- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
11
- Author / Contributor
- Filter by Author / Creator
-
-
Bowen, Charles T (2)
-
Byers, Todd A (2)
-
Glass, Gary A (2)
-
Kaur_Saini, Darshpreet (2)
-
Nook, Cory (2)
-
Rout, Bibhudutta (2)
-
Parashar, Mritunjaya (1)
-
Sharma, Mohin (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
- Filter by Editor
-
-
Bogdanović (1)
-
Ikeda, Tokihiro (1)
-
Iva (1)
-
Lorenz, Katharina (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Bogdanović; Iva; Lorenz, Katharina (Ed.)PIXE analysis was conducted on p8 fisher brand filter paper samples soaked in elemental standard solutions to determine the minimum detectable levels of Al, Si, P, S, Cl, K, Ca, Cr, Fe, Ni, Cu, and Se. All samples were analyzed with beam parameters of 2 µC incident charge, and beam current of less than 2 nA at 2 MeV beam energy. Minimum detectable levels were obtained by analyzing the x-ray spectrum in the GeoPIXE analysis package, and the data for each element would be averaged over all collected spectra. The minimum detectable level in parts per million was found to be on average 9.59 for Al, 4.6 for Si, 3.23 for P, 2.27 for S, 1.82 for Cl, 1.15 for K, 0.88 for Ca, 0.51 for Cr, 0.07 for Mn, 0.54 for Fe, 1.59 for Ni, 2.0 for Zn, 1.55 for Cu, and 6.5 for Se. Minimal deviation from the averaged values was observed, except in cases where samples contained high concentrations of elements with overlapping X-ray energies.more » « lessFree, publicly-accessible full text available December 1, 2025
-
Kaur_Saini, Darshpreet; Byers, Todd A; Nook, Cory; Bowen, Charles T; Sharma, Mohin; Parashar, Mritunjaya; Glass, Gary A; Rout, Bibhudutta (, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms)Ikeda, Tokihiro (Ed.)We have investigated the concentration and correlation between the macro and micro-elements found in an herbal plant named Ocimum sanctum (Tulsi) leaf, using Particle-Induced X-ray Emission (PIXE) spectroscopy. The leaf area was analyzed with a 2 MeV scanning proton micro-beam with a spot size of ~ 1 square micrometer. This study is focused on exploring the correlation between the elemental maps generated using X-ray spectra with micro-PIXE. Two types of correlations i.e., elemental, and concentration-phase correlations were examined. The elemental maps are used to find the relation between the spatial distribution of the elements present in the scanned region while the correlation maps help in understanding which phase corresponds to the region of selected concentration ratios. All the elemental concentrations were determined with the detection limits in ng/mg. The analysis of macro-elements showed that the potassium concentration was highest and phosphorus exhibited the lowest concentration whereas iron was found to be highest in the category of trace or microelements. Moreover, broad-beam runs were also performed on the samples to examine the trend for elemental concentrations.more » « less
An official website of the United States government
